HEIDEN power GmbH

Contact us

 

+49-8196-9988-0

info@heidenpower.com


Office hours:
Monday – Thursday: 08.00 – 17.00 Uhr
Friday: 08.00 – 14.30 Uhr

Address:
HEIDEN power GmbH
Am Wiesengrund 1
86932 Pürgen / Germany


Regenerative ERI DC-Last

PMLA Multilast

DC SINK

PMLA Multiload

The multi-channel

Multikanal DC Last

Short profile

The multi-channel load PMLA combines up to 12 load channels / modules in a compact 19“ enclosure with only two height units. All load channels are galvanically separated from each other, making multi-channel test systems such as burn-in facilities very easy to configure. A master device, which has both a graphical user interface and various data interfaces, controls all load channels of the system, which is extended by one or more slave devices if required.

Configuration

The PMLA Electronic Multichannel Load has up to three cooler units with four installation sites for load modules each, depending on the version. Modules with different powers of 150 W, 300 W, 450 W or 600 W are available. Depending on the power, a module occupies one (150 W), two (300 W), three (450 W) or four internal slots for 600 W per single channel.

Discharge function, Energy storage test

The discharge function tests energy storage devices such as batteries, ultracaps, electrolytic capacitors and solar panels and so on by converting them into CC-, CP- or CR operation can be discharged. The discharge function can be combined with the list function, so that a pulsed discharge is possible. An IUa discharge in the combined CC+CV, CR+CV or CP+CV modes is also possible: Thereby discharges the DUT with constant current, resistance or power up to a defined voltage. This voltage is then kept constant until a defined minimum current is reached. Stop criteria are charge, energy, time, current and voltage.

  • Configurable Multichannel Load
  • Up to 12 channels in 19“, 2 U
  • Channel expansion via slave devices
  • Maximum 72 channels per system
  • Modules 150 W – 300 W – 450 W – 600 W
  • Voltages 40 V – 60 V – 120 V – 240 V
  • Currents from 1 A to 120 A
  • Dynamic loading

DescriptionPowerVoltageCurrentDynamicDimensions
MA15-04C30150 W40 V30 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-06C20150 W60 V20 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-06C5150 W60 V5 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-12C10150 W120 V10 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-12C2150 W120 V2 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-24C5150 W240 V5 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-24C1150 W240 V1 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-04C60300 W40 V60 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-06C40300 W60 V40 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-06C10300 W60 V10 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-12C20300 W120 V20 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-12C4300 W120 V4 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-24C10300 W240 V10 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-24C2300 W240 V2 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-04C90450 W40 V90 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-06C60450 W60 V60 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-06C15450 W60 V15 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-12C30450 W120 V30 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-12C6450 W120 V6 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-24C15450 W240 V15 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-24C3450 W240 V3 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-04C120600 W40 V120 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-06C80600 W60 V80 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-06C20600 W60 V20 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-12C40600 W120 V40 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-12C8600 W120 V8 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-24C20600 W240 V20 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-24C4600 W240 V4 A200 µs19“ x 2 U - 485 x 88 x 485 mm
DC-LAST

PMLA Multiload

The multi-channel

Multikanal DC Last

Short profile

The multi-channel load PMLA combines up to 12 load channels / modules in a compact 19“ enclosure with only two height units. All load channels are galvanically separated from each other, making multi-channel test systems such as burn-in facilities very easy to configure. A master device, which has both a graphical user interface and various data interfaces, controls all load channels of the system, which is extended by one or more slave devices if required.

Configuration

The PMLA Electronic Multichannel Load has up to three cooler units with four installation sites for load modules each, depending on the version. Modules with different powers of 150 W, 300 W, 450 W or 600 W are available. Depending on the power, a module occupies one (150 W), two (300 W), three (450 W) or four internal slots for 600 W per single channel.

Discharge function, Energy storage test

The discharge function tests energy storage devices such as batteries, ultracaps, electrolytic capacitors and solar panels and so on by converting them into CC-, CP- or CR operation can be discharged. The discharge function can be combined with the list function, so that a pulsed discharge is possible. An IUa discharge in the combined CC+CV, CR+CV or CP+CV modes is also possible: Thereby discharges the DUT with constant current, resistance or power up to a defined voltage. This voltage is then kept constant until a defined minimum current is reached. Stop criteria are charge, energy, time, current and voltage.

  • Configurable Multichannel Load
  • Up to 12 channels in 19“, 2 U
  • Channel expansion via slave devices
  • Maximum 72 channels per system
  • Modules 150 W – 300 W – 450 W – 600 W
  • Voltages 40 V – 60 V – 120 V – 240 V
  • Currents from 1 A to 120 A
  • Dynamic loading

DescriptionPowerVoltageCurrentDynamicDimensions
MA15-04C30150 W40 V30 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-06C20150 W60 V20 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-06C5150 W60 V5 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-12C10150 W120 V10 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-12C2150 W120 V2 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-24C5150 W240 V5 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA15-24C1150 W240 V1 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-04C60300 W40 V60 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-06C40300 W60 V40 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-06C10300 W60 V10 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-12C20300 W120 V20 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-12C4300 W120 V4 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-24C10300 W240 V10 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA30-24C2300 W240 V2 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-04C90450 W40 V90 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-06C60450 W60 V60 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-06C15450 W60 V15 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-12C30450 W120 V30 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-12C6450 W120 V6 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-24C15450 W240 V15 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA45-24C3450 W240 V3 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-04C120600 W40 V120 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-06C80600 W60 V80 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-06C20600 W60 V20 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-12C40600 W120 V40 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-12C8600 W120 V8 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-24C20600 W240 V20 A200 µs19“ x 2 U - 485 x 88 x 485 mm
MA60-24C4600 W240 V4 A200 µs19“ x 2 U - 485 x 88 x 485 mm