HEIDEN power GmbH

Contact us

 

+49-8196-9988-0

info@heidenpower.com


Office hours:
Monday – Thursday: 08.00 – 17.00 Uhr
Friday: 08.00 – 14.30 Uhr

Address:
HEIDEN power GmbH
Am Wiesengrund 1
86932 Pürgen / Germany


DC Quelle Autorange

PSx Series

DC-QUELLE

HEA-PS, -PSE, -PSI, -PSB Series

DC Quellen DC Stromversorgungen

Series HEA-PS, -PSE, -PSI, -PSB

One series, many variations. What are the differences between the device series? We have compiled the most common questions for you to help you make a quick selection.

What does „autorange“ mean on these devices?

» Due to the flexible output characteristic curve, the output stage can drive a higher current at lower voltage and apply a higher voltage at lower current. All series have an autorange area.

Several devices should be connected in parallel for higher power can be operated. Which devices are suitable special?

» We recommend devices with master-slave interface, that is, the HEA-PSE, -PSI or -PSB. The Master-Slave-Interface ensures even power distribution and adds up current and power. You only control or the master device.

How do the operating concepts distinguish?

» The series HEA-PS and -PSE have a color TFT
» Display, operation is via rotary encoder and push button.
» The HEA-PSI and -PSB series have a Color display with touch function.
» The simultaneous display of target and actual values is possible at all devices.

Which devices have a functional generator and what can it be used for


» The HEA-PSI and -PSB series are supplied ex works with a function generator. There can be U(t), I(t), U(I) and I(U) characteristics and functions programmed. This enables a selfsufficient operation e.g. as PV simulator or battery tester.

Which interfaces are possible, which are already integrated?

The HEA-PS and -PSE series have the most common Interfaces permanently installed.

» The HEA-PSI and -PSB series also feature a digital slot, in order to provide further digital fieldbus interfaces integrate. These can be upgraded at any time.

HEA-PS9000 1U up to 1,5 kW

1 HE DC Versorgung

HEA-PS & PSE9000 2U up to 3 kW

Kleine DC Quelle ohne Autoranging

HEA-PS & PSE9000 3U up to 15 kW

DC Netzgerät Stromversorgung

HEA-PSI9000 2U bis 3 kW

DC Quelle 2 HE

HEA-PSI9000 3U up to 15 kW

DC Quelle mit Autoranging

HEA-PSI and PSB10000 4U 30 kW

Bidirektionale Stromversorgung DC
FeaturesHEA-PS9000HEA-PSE9000HEA-PSI9000HEA-PSB9000HEA-PSI10000HEA-PSB10000
Autorange Ausgangxxxxxx
DC-Sourcexxxxxx
DC-Source-Sinkxx
Power1 kW...15 kW3,3 kW...15 kW1 kW...15 kW±2,5 kW...15 kW30 kW±30 kW
Voltage to1 kW...6,6 kW
max. 750 V

10 kW
max. 1.000 V

15 kW
max. 1.500 V
3,3 kW...6,6 kW
max. 750 V

10 kW
max. 1.000 V

15 kW
max. 1.500 V
1 kW...6,6 kW
max. 750 V

10 kW
max. 1.000 V

15 kW
max. 1.500 V
±2,5 kW...10 kW
max. 750 V

±15 kW, max. 1.500 V
max. 2.000 Vmax. 2.000 V
Function Generatorxxxx
Front-USB for Sticks
Programming, Logging
xxxx
TFT color displayxxxxxx
Touch operationxxxx
Operating mode CV, CC, CPxxxxxx
Operating mode CRxxxx
Analogue Interfacexxxxxx
USBxxxxxx
LANxoooxx
Interface slotooxxx
Extension module:
CANopen
CAN
RS232
Profibus
Ethernet/IPUSB
Profinet-IO
Modbus-TCP
ooooo
Master-Slave Bus for parallel connectionxxxxx
PV Simulationxxxx
Operating softwarexxxxxx
Multi-Control software up to 20 devicesoooooo
Battery testxx
Akku-Simulation (SoC)o
Sense connectionxxxxxx
Protection functions: OVP, OCP, OPP, OTPxxxxxx
x = Built in serially
o = optional available
– = not available
DC-QUELLE

HEA-PS, -PSE, -PSI, -PSB Series

DC Quellen DC Stromversorgungen

Series HEA-PS, -PSE, -PSI, -PSB

One series, many variations. What are the differences between the device series? We have compiled the most common questions for you to help you make a quick selection.

What does „autorange“ mean on these devices?

» Due to the flexible output characteristic curve, the output stage can drive a higher current at lower voltage and apply a higher voltage at lower current. All series have an autorange area.

Several devices should be connected in parallel for higher power can be operated. Which devices are suitable special?

» We recommend devices with master-slave interface, that is, the HEA-PSE, -PSI or -PSB. The Master-Slave-Interface ensures even power distribution and adds up current and power. You only control or the master device.

How do the operating concepts distinguish?

» The series HEA-PS and -PSE have a color TFT
» Display, operation is via rotary encoder and push button.
» The HEA-PSI and -PSB series have a Color display with touch function.
» The simultaneous display of target and actual values is possible at all devices.

Which devices have a functional generator and what can it be used for


» The HEA-PSI and -PSB series are supplied ex works with a function generator. There can be U(t), I(t), U(I) and I(U) characteristics and functions programmed. This enables a selfsufficient operation e.g. as PV simulator or battery tester.

Which interfaces are possible, which are already integrated?

The HEA-PS and -PSE series have the most common Interfaces permanently installed.

» The HEA-PSI and -PSB series also feature a digital slot, in order to provide further digital fieldbus interfaces integrate. These can be upgraded at any time.

HEA-PS9000 1U up to 1,5 kW

1 HE DC Versorgung

HEA-PS & PSE9000 2U up to 3 kW

Kleine DC Quelle ohne Autoranging

HEA-PS & PSE9000 3U up to 15 kW

DC Netzgerät Stromversorgung

HEA-PSI9000 2U bis 3 kW

DC Quelle 2 HE

HEA-PSI9000 3U up to 15 kW

DC Quelle mit Autoranging

HEA-PSI and PSB10000 4U 30 kW

Bidirektionale Stromversorgung DC
FeaturesHEA-PS9000HEA-PSE9000HEA-PSI9000HEA-PSB9000HEA-PSI10000HEA-PSB10000
Autorange Ausgangxxxxxx
DC-Sourcexxxxxx
DC-Source-Sinkxx
Power1 kW...15 kW3,3 kW...15 kW1 kW...15 kW±2,5 kW...15 kW30 kW±30 kW
Voltage to1 kW...6,6 kW
max. 750 V

10 kW
max. 1.000 V

15 kW
max. 1.500 V
3,3 kW...6,6 kW
max. 750 V

10 kW
max. 1.000 V

15 kW
max. 1.500 V
1 kW...6,6 kW
max. 750 V

10 kW
max. 1.000 V

15 kW
max. 1.500 V
±2,5 kW...10 kW
max. 750 V

±15 kW, max. 1.500 V
max. 2.000 Vmax. 2.000 V
Function Generatorxxxx
Front-USB for Sticks
Programming, Logging
xxxx
TFT color displayxxxxxx
Touch operationxxxx
Operating mode CV, CC, CPxxxxxx
Operating mode CRxxxx
Analogue Interfacexxxxxx
USBxxxxxx
LANxoooxx
Interface slotooxxx
Extension module:
CANopen
CAN
RS232
Profibus
Ethernet/IPUSB
Profinet-IO
Modbus-TCP
ooooo
Master-Slave Bus for parallel connectionxxxxx
PV Simulationxxxx
Operating softwarexxxxxx
Multi-Control software up to 20 devicesoooooo
Battery testxx
Akku-Simulation (SoC)o
Sense connectionxxxxxx
Protection functions: OVP, OCP, OPP, OTPxxxxxx
x = Built in serially
o = optional available
– = not available