HEIDEN power GmbH

Contact us

 

+49-8196-9988-0

info@heidenpower.com


Office hours:
Monday – Thursday: 08.00 – 17.00 Uhr
Friday: 08.00 – 14.30 Uhr

Address:
HEIDEN power GmbH
Am Wiesengrund 1
86932 Pürgen / Germany


HEIDEN AC-Quellen

HE-ACS and HE-ACS3, HE-ACQ and HE-ACQ3

AC SOURCE

HE-ACS and HE-ACS3

HE-ACQ and HE-ACQ3

AC and DC source single and three-phases

HEIDEN AC-Quellen

Linear or pulsed

The linearly controlled AC and DC sources of the HEIDEN HE-ACS series are used to simulate frequencies, voltages, waveforms, phase angles and currents in various single- and three-phase grids in order to investigate the behavior of components, motors and devices in normal operation or at under- and overvoltages. The AC signal can also be programmed with a DC offset.

Single or three-phase

The HEIDEN AC sources of the HE-ACS and HE-ACQ series are available as single-phase as well as three-phases version. Three of the proven power stages are used in the three-phases systems. Phase angles and the programmed values are synchronized via an internal bus. At higher power levels, the devices are installed in a mobile rack for maximum flexibility. At the rack version we are happy to meet customer-specific requirements.

Programmable

Besides sinusoidal signals, many other signal variants are possible. With the integrated flicker simulation, short-term power failures can be simulated.

Measurement acquisition

The devices of the HE-ACS and HE-ACQ families measure automatically output voltage, RMS current, average and peak current, active power, reactive power, apparent power, power factor and crest factor. These quantities are displayed simultaneously on the large graphic display.The user has an overview of the entire process at all times and does not need to connect additional measuring devices for most tasks.

  • Simulation of single-phase and three-phase grids
  • Output voltages up to 700 VAC/1.000 VDC
  • Variable frequency of up to 2.000 Hz
  • Signal shapes sine, rectangle, triangle
  • Maximum currents up to 600 A per phase
  • Indication via large, graphic display
  • Measurements of voltage, current effective, mean value, peak current, active power, reactive power, apparent power, power factor, crest factor
  • Constant voltage and constant current operation
  • Script control system
  • Cos Phi 0,7…1 (special versions on request)
  • Linear output stage
  • High signal quality

HE-ACS-Models

DescriptionPowerVoltageCurrentDimensions
HE-ACS-250250 VA300 / 425 V3 A19" x 4 HE x 434,5 mm
HE-ACS-500500 VA300 / 425 V6 A19" x 4 HE x 434,5 mm
HE-ACS-10001.000 VA300 / 425 V10 A19" x 6 HE x 434,5 mm
HE-ACS-20002.000 VA300 / 425 V15 A19" x 6 HE x 434,5 mm
HE-ACS-30003.000 VA300 / 425 V20 A19" x 10 HE x 434,5 mm
HE-ACS-40004.000 VA300 / 425 V30 A19" x 16 HE x 600 mm
HE-ACS-50005.000 VA300 / 425 V35 A19" x 16 HE x 600 mm
HE-ACS-60006.000 VA300 / 425 V40 A19" x 16 HE x 600 mm
HE-ACS-70007.000 VA300 / 425 V50 A19" x 20 HE x 800 mm
HE-ACS-80008.000 VA300 / 425 V60 A19" x 20 HE x 800 mm
HE-ACS-90009.000 VA300 / 425 V70 A19" x 25 HE x 800 mm
HE-ACS-1000010.000 VA300 / 425 V80 A19" x 25 HE x 800 mm



HE-ACQ-Models

DescriptionPowerVoltageCurrentDimensions
HE-ACQ-250250 VA300 / 425 V3 A19" x 3 HE x 620 mm
HE-ACQ-500500 VA300 / 425 V6 A19" x 3 HE x 620 mm
HE-ACQ-15001.500 VA300 / 425 V10 A19" x 3 HE x 620 mm
HE-ACQ-20002.000 VA300 / 425 V15 A19" x 6 HE x 620 mm
HE-ACQ-30003.000 VA300 / 425 V20 A19" x 6 HE x 620 mm
HE-ACQ-45004.500 VA300 / 425 V30 A19" x 9 HE x 620 mm
HE-ACQ-50005.000 VA300 / 425 V35 A19" x 9 HE x 620 mm
HE-ACQ-60006.000 VA300 / 425 V40 A19" x 9 HE x 620 mm
HE-ACQ-75007.500 VA300 / 425 V50 A19" x 9 HE x 620 mm
HE-ACQ-80008.000 VA300 / 425 V60 A19" x 12 HE x 620 mm
HE-ACQ-90009.000 VA300 / 425 V70 A19" x 12 HE x 620 mm
HE-ACQ-1050010.500 VA300 / 425 V80 A19" x 12 HE x 620 mm
HE-ACQ-1200012.000 VA300 / 425 V90 A19" x 18 HE x 620 mm
AC SOURCE

HE-ACS and HE-ACS3

HE-ACQ and HE-ACQ3

AC and DC source single and three-phases

HEIDEN AC-Quellen

Linear or pulsed

The linearly controlled AC and DC sources of the HEIDEN HE-ACS series are used to simulate frequencies, voltages, waveforms, phase angles and currents in various single- and three-phase grids in order to investigate the behavior of components, motors and devices in normal operation or at under- and overvoltages. The AC signal can also be programmed with a DC offset.

Single or three-phase

The HEIDEN AC sources of the HE-ACS and HE-ACQ series are available as single-phase as well as three-phases version. Three of the proven power stages are used in the three-phases systems. Phase angles and the programmed values are synchronized via an internal bus. At higher power levels, the devices are installed in a mobile rack for maximum flexibility. At the rack version we are happy to meet customer-specific requirements.

Programmable

Besides sinusoidal signals, many other signal variants are possible. With the integrated flicker simulation, short-term power failures can be simulated.

Measurement acquisition

The devices of the HE-ACS and HE-ACQ families measure automatically output voltage, RMS current, average and peak current, active power, reactive power, apparent power, power factor and crest factor. These quantities are displayed simultaneously on the large graphic display.The user has an overview of the entire process at all times and does not need to connect additional measuring devices for most tasks.

  • Simulation of single-phase and three-phase grids
  • Output voltages up to 700 VAC/1.000 VDC
  • Variable frequency of up to 2.000 Hz
  • Signal shapes sine, rectangle, triangle
  • Maximum currents up to 600 A per phase
  • Indication via large, graphic display
  • Measurements of voltage, current effective, mean value, peak current, active power, reactive power, apparent power, power factor, crest factor
  • Constant voltage and constant current operation
  • Script control system
  • Cos Phi 0,7…1 (special versions on request)
  • Linear output stage
  • High signal quality

HE-ACS-Models

DescriptionPowerVoltageCurrentDimensions
HE-ACS-250250 VA300 / 425 V3 A19" x 4 HE x 434,5 mm
HE-ACS-500500 VA300 / 425 V6 A19" x 4 HE x 434,5 mm
HE-ACS-10001.000 VA300 / 425 V10 A19" x 6 HE x 434,5 mm
HE-ACS-20002.000 VA300 / 425 V15 A19" x 6 HE x 434,5 mm
HE-ACS-30003.000 VA300 / 425 V20 A19" x 10 HE x 434,5 mm
HE-ACS-40004.000 VA300 / 425 V30 A19" x 16 HE x 600 mm
HE-ACS-50005.000 VA300 / 425 V35 A19" x 16 HE x 600 mm
HE-ACS-60006.000 VA300 / 425 V40 A19" x 16 HE x 600 mm
HE-ACS-70007.000 VA300 / 425 V50 A19" x 20 HE x 800 mm
HE-ACS-80008.000 VA300 / 425 V60 A19" x 20 HE x 800 mm
HE-ACS-90009.000 VA300 / 425 V70 A19" x 25 HE x 800 mm
HE-ACS-1000010.000 VA300 / 425 V80 A19" x 25 HE x 800 mm



HE-ACQ-Models

DescriptionPowerVoltageCurrentDimensions
HE-ACQ-250250 VA300 / 425 V3 A19" x 3 HE x 620 mm
HE-ACQ-500500 VA300 / 425 V6 A19" x 3 HE x 620 mm
HE-ACQ-15001.500 VA300 / 425 V10 A19" x 3 HE x 620 mm
HE-ACQ-20002.000 VA300 / 425 V15 A19" x 6 HE x 620 mm
HE-ACQ-30003.000 VA300 / 425 V20 A19" x 6 HE x 620 mm
HE-ACQ-45004.500 VA300 / 425 V30 A19" x 9 HE x 620 mm
HE-ACQ-50005.000 VA300 / 425 V35 A19" x 9 HE x 620 mm
HE-ACQ-60006.000 VA300 / 425 V40 A19" x 9 HE x 620 mm
HE-ACQ-75007.500 VA300 / 425 V50 A19" x 9 HE x 620 mm
HE-ACQ-80008.000 VA300 / 425 V60 A19" x 12 HE x 620 mm
HE-ACQ-90009.000 VA300 / 425 V70 A19" x 12 HE x 620 mm
HE-ACQ-1050010.500 VA300 / 425 V80 A19" x 12 HE x 620 mm
HE-ACQ-1200012.000 VA300 / 425 V90 A19" x 18 HE x 620 mm